Avaya X330WAN Network Router User Manual


 
Controller CLI Commands (X330WAN-2DS1 Only)
Avaya X330WAN User’s Guide 127
Remote alarm Any alarms detected by the controller are displayed. The possible
alarms are:
Transmitter is sending remote alarm.
Transmitter is sending alarm indication signal (AIS).
Receiver has loss of signal.
Receiver is receiving AIS.
Receiver has loss of frame.
Receiver has remote alarm.
Receiver has no alarms.
Receiver has a major alarm.
Framing Shows the current framing type. The default framing type for E1
is CRC4. The default framing type for T1 is SF.
Line Code Displays the current line code. The default line code for E1 is
HDB3. The default line code for T1 is AMI.
Clock Source Displays the current clock source. The possible clock sources are
either Line or Internal.
Channel Group Displays the channel group number and timeslots.
Data in current
interval
(347 seconds
elapsed)
Displays the current accumulation period (from 1-900 seconds),
which rolls into a 24 hour accumulation every 15 minutes. The
oldest 15 minute period falls off the back of the 24 hour
accumulation buffer.
Line Code
Violations
Displays either no line code violations, the occurrence of a
Bipolar Violation, or the occurrence of an Excessive Zeros error
event.
Path Code
Violations
Displays one of the following:
No path code violations.
A frame synchronization bit error in the SF (for T1) and
no- CRC4 (for E1) frame types.
A CRC4 error in the ESF (for T1) and CRC4 (for E1) frame
types.
Slip Secs Displays if there is a replication or deletion of the payload bits of
a domestic trunk interface (DS1) frame. A slip might happen
when there is a difference between the timing of a synchronous
receiving terminal and the received signal.
Fr Loss Secs Displays the number of seconds an Out of Frame (OOF) error is
detected.