11. Input Slots for ViewScape
Luma Transient Improvement (LTI)
LTI accentuates the transient between two parts of the image with different intensity. The degree of im-
provement can be adjusted with the slider bar.
When on 0, the image is displayed without LTI. 7 represents the sharpest LTI.
Field Insert
Field insert can be ON or OFF.
With Field Insert ON, both fields of a interlaced image will be added together to form one de-interlaced
image.
When Field insert is ON, the De-Interlacing mode has no function.
11.3.3 Input Gain Equalizing
Overview
Each gain can be adjusted between 0 and 255 (-3dB and +6dB).
Any value can be entered by
• clicking first in digit box and entering the desired value or
• sliding the corresponding slider to the desired value.
3 values, -3dB, 0dB, +6dB or preprogrammed and can be selected by clicking on the corresponding indi-
cation.
The slider jumps immediately to correct value.
The following input gain adjustments are possible:
• Luminance Gain
•V-Gain
•U-Gain
11.3.4 Dynamic Image Stabilizer (DIS)
Value
between 0 and 7.
Slide
magnified/normal.
Magnified for DIS effectivity. Useful for noisy video content.
Flash
ON/OFF
To compensate for fast moving images, the DIS Flash will detect such movements and put the DIS tem-
porary off.
DIS sensitivity
Select the amplitude sensitivity of the DIS
For low video quality sources choose Luma Low/ Chroma Low for video sources of high quality choose
Luma High/ Chroma High (preferable)
DIS filter
Select the frequency sensitivity of the DIS
102