Cisco Systems 10008 Network Router User Manual


 
3-23
Cisco 10008 Router Hardware Installation Guide
OL-0659-13
Chapter 3 Installing the Cisco 10008 Router
Connecting AC Power to the Cisco 10008 Router
There are five styles of AC-input power supply power cords available (differing in plug type); make sure
you have the correct style for your site (see Table 3-3, Figure 3-22, and Figure 3-23.) All AC-input
power supply power cords measure 14 feet (4.3 m). Cisco recommends that you:
Install an uninterruptible power source where possible.
Install proper grounding to avoid damage from lightning and power surges (see “Attaching the
Grounding Cable” section on page 3-14).
Table 3-3 lists the nominal and acceptable value ranges for source AC power.
Figure 3-22 AC Power Cords
Table 3-3 Source AC Power Specifications
Specifications Nominal Value Acceptable Range
AC input voltage 100 to 240 VAC, single phase 90 to 255 VAC
AC input line frequency 50/60 Hz 47 to 63 Hz
AC input current 15 A @100 VAC
7 A @240 VAC
1 North American/Japanese plug, L6-20 20A 4 Italian plug, CEI 23-16/VII 10A
2 European plug, CEE 7/7 16A 5 Australian/Argentinean plug, AS 3112 10A
3 North American plug, NEMA 5-20P 20A 6 United Kingdom plug, BS 1363 13A
132841
1
2
3
4
5
6