TELEPHONE INTERFACE MODULE (TIM)
14-31
Figure 14-29 6132 TELLABS CARD
S4
S4
R34
S5
ADDED CAPS
TOP
FRONT
14.15 FCC USER INSTRUCTIONS AND
CUSTOMER INFORMATION
NOTE: This information does not apply to the 4-Wire
E&M. The 4-Wire E&M does not direct connect to the
telephone company equipment.
In order to connect a DID or 2WY system to the
network, provide the telephone company with:
1. The quantities and USOC numbers of the required
jacks (Table 14-12).
2. The sequence for trunk connections.
3. The facility interface codes by position.
4. The ringer equivalence number or service order
code, as applicable, by the position.
This equipment complies with Part 68 of the FCC
rules. A label with the FCC registration number and
Ringer Equivalence number (as applicable) for this
equipment is on the rear access door.
The REN (as applicable to the service provided
by the Telco) is used to determine the number of
devices you may connect to the telephone line and still
have assurance that all devices ring properly when
called. In most, but not all areas, the sum of the RENs
of all devices should not exceed 5.0. To be certain of
the number of devices you may connect to each line,
call the local Telco and request the maximum allow-
able REN for the calling area.
If any of your telephone equipment causes harm
to the network, the Telco may discontinue your
service. If possible, you will be notified in advance,
otherwise you will be notified as soon as possible.
You will also be advised of your rights to file a
complaint with the FCC.
The Telco may make changes in its facilities,
equipment operations, or procedures, that could affect
the proper operation of your equipment. Advance
notice will be given to provide an opportunity to main-
tain uninterrupted service.
In the event repairs are needed on this equipment,
please contact: E.F. Johnson Co., Customer Service
Department, Waseca, MN 56093-0514.
FCC rules prohibit the connection of customer
provided equipment to central office implemented
coin telephone service. Connection to party lines is
subject to state tariffs. (Contact your state public
service commission for information.)
Table 14-12 SYSTEM INFORMATION
TYPE OF INTERFACE USOC REN SOC FIC
DID (-660 Card Interface)
Loop/Ground Start (PSTN) (-670) Card Interface
Reg # ATHUSA-61094-MF-E
RJ-21X
RJ-21X
------
2.3B(AC)
9.0F
9.0F
02V2-T
02LS2/02GS2