Netlog
Use this control panel to configure the Netlog utility. By configuring Netlog using the control panel, Netlog remains running
across a warmboot. However, please note that:
l Netlog first stores data to a file named netlog0.cap, then netlog1.cap. Any time the current file reaches maximum size,
Netlog switches to the other file.
l If the log file is stored in the root directory, any previous data is lost and a new log file started after the warmboot.
l If the log file is stored in \System, all previous data is saved across the warmboot.
l If Netlog is enabled across the warmboot, a series of brief popups may be displayed during the boot cycle. No user
interaction is required.
Command
Command Function
options Specifies the option to perform. See the table below for the option parameters and values.
load Loads and starts Netlog.
start Starts the Netlog process of logging the network traffic.
stop Stops Netlog from logging network traffic.
unload Unloads Netlog.
Options
Options Function
pkt_size in
bytes
Specifies the maximum packet size captured in bytes. This option should only be run after you have called load
and stop. Default is 5000.
cap_size in
bytes
Specifies the maximum size of Netlog0.cap or Netlog1.cap in bytes. This option should only be run after you
have called load and stop. Default is 500,000.
.cap file
Specifies the name of the file to which network traffic information is saved. This option should only be run after
you have called load and stop. Default is \netlog.