IBM CDI5UG1107 Computer Accessories User Manual


 
Submitting a Job on a Remote Node 111
Optional Parameters
The following parameters, listed alphabetically, are optional. Unless otherwise noted, the parameters apply to
all remote node environments.
BATCHID(idname)
specifies the VM remote Virtual Machine ID name. The valid range is 1–8 characters.
CLASS(n)
determines the node-to-node session where a Sterling Connect:Direct operation can execute. The
CLASS is a number from 1–255. If you do not specify the CLASS parameter, it defaults to the
maximum number of sessions defined in the mode description for the communications environment.
CRC(*INITPARMS
|I*NETMAP|N*OFF|F*ON|O)
Determines whether node and process statement overrides for Cyclic Redundancy Check (CRC) are
allowed. If this value is set to *OFF, setting overrides for CRC checking will be ignored. The default
value is *INITPARMS.
*INITPARMS
(or *I) specifies that the CRC setting is determined by the value for the initialization
parameter TCP.CRC.
*NETMAP (or *N) specifies that the CRC setting is determined by the value for the NETMAP
parameter, Cyclic Redundancy Check. The value for the initialization parameter TCP.CRC must be
set to *ON and the value for the initialization parameter TCP.CRC.OVERRIDE must be set to *YES.
*OFF (or *F) specifies that CRC is disabled.
*ON (or *O) specifies that CRC is enabled.
JOBFILE(filename)
specifies the name of the file that contains the job to be submitted. This file must already exist on the
node where the job is to be submitted.
LINK(CMS-file-information)
specifies where the CMS file is located. This parameter allows you to access the VM CMS file.
owner id specifies the user ID for the owner of the CMS minidisk where the file is located.
owner password specifies the password for the CMS minidisk where the file is located. This
parameter accepts 1–8 characters. The default is ALL.
LINK access mode specifies the LINK access mode. The following entries are valid:
W for primary read/write
M for primary multiple access
R for primary read only
RR for primary and secondary read only
WR for primary read/write; alternate read only
MW for primary multiple access; alternate read/write
virtual address specifies the virtual address of the disk where the CMS file is located. A three-digit
number is valid.
NOTIFY(userid)
specifies the user ID on the local node to receive status messages that are directed to the message
queue of the user.
Note: The CLASS parameter is not used by Sterling Connect:Direct for i5/OS.