84 IBM Sterling Connect:Direct for i5/OS User’s Guide
PNODEID(id, pswd, newpswd)
specifies security user IDs and passwords at the local node. This parameter should only be used to
validate security with a different ID than the one you used to sign on to Sterling Connect:Direct.
PNODEID is not used when both the ID and password match on the local and remote nodes.
id specifies the security ID passed to the security system on the local node (1–10 alphanumeric
characters).
pswd specifies the current security password for the specified ID. This parameter is used by the
security system on the local node to validate the current security password (1–10 alphanumeric
characters). This is optional unless the user has security set to require a password.
newpswd specifies the new security password. It is used by the security system to change the current
security password to the new security password (1–10 alphanumeric characters).
PRTY(n)
specifies the priority of the operation. High numbers indicate high priorities; low numbers indicate
low priorities. Use this priority only for selection within CLASS. It does not affect transmission
priority. The range is from 0–15. The default is *INITPARMS. Type DSPPFM INITPARMS to
view the default.
RMTWORK(*YES|*NO
)
specifies whether a remote Process can run on the session after Sterling Connect:Direct for i5/OS has
completed its Process on the session.
*YES allows the remote Process to run on the session after Sterling Connect:Direct for i5/OS
completes its Process.
*NO
terminates the session after Sterling Connect:Direct for i5/OS executes the command function.
*NO is the default for this parameter.
SACCT(snode-accounting-data)
specifies the accounting data for the remote node. The maximum length of the accounting data is 256
characters. If special characters are part of the accounting data, the string must be enclosed in single
quotation marks. This parameter is valid for z/OS nodes only.
SECOPTIONS(* *)
specifies Encryption and Digital Signature values.
Encryption specifies if data encryption is to be performed and what algorithm to use.
Digital Signature specifies if a digital signature is created during file transmission.
SNODEID(id, pswd, newpswd)
specifies security user IDs and passwords at the remote node. Use this parameter only to validate
security with a different ID than the one you used to sign on to Sterling Connect:Direct.
Note: Although you can specify a value for newpswd, Sterling Connect:Direct for i5/OS does not
support this parameter.
Note: The SECOPTIONS parameter is valid only if Sterling Connect:Direct Secure Plus is
installed. For information about these parameters, refer to the IBM Sterling Connect:Direct
Secure Plus for i5/OS Implementation Guide.
Note: Parameter values are case sensitive.