IBM CDI5UG1107 Computer Accessories User Manual


 
Running a Remote Task 97
pswd specifies the current security password for the specified ID. The security system at the local
node can use this parameter to validate the current security password (1–10 alphanumeric characters).
This is optional unless the user has security set to require a password.
newpswd specifies the new security password. The security system can use this parameter to change
the current security password to the new security password (1–10 alphanumeric characters).
RMTWORK(*YES|*NO
)
specifies whether a remote Process can run on the session after Sterling Connect:Direct for i5/OS has
completed its Process on the session.
*YES allows a remote Process to run on the session after the Sterling Connect:Direct for i5/OS
completes its Process.
*NO
terminates the session after Sterling Connect:Direct for i5/OS executes the command function.
*NO is the default.
SACCT(snode-accounting-data)
specifies the accounting data for the remote node. The maximum length of the accounting data is 256
characters. If special characters are part of the accounting data, the string must be enclosed in single
quotation marks.
SNODEID(id, pswd, newpswd)
specifies security user IDs and passwords at the remote node. This parameter should only be used to
validate security with a different ID than the one you used to sign on to Sterling Connect:Direct.
id specifies the security ID passed to the security system on the remote node (1–64 alphanumeric
characters).
pswd specifies the current security password and is used by the security system on the SNODE to
validate the current security password (1–64 alphanumeric characters). This parameter is optional
unless the user has security set to require a password.
newpswd specifies the new security password and is used by the security system to change the current
security password to the new security password (1–64 alphanumeric characters).
TRACEOPT
Trace Instructions
(L, S, F, C, X, K, D, H, V, W, P,|*NONE|*ALL|*EXT| *COMMON|*INITPARMS|*CURRENT
specifies the trace bits that define functions to be traced by Sterling Connect:Direct for i5/OS. The
following are valid options:
L enables the main line logic trace for all components.
S enables the Process step logic trace.
F enables the file handler trace.
C enables the communications logic trace.
X enables the XDR trace.
K enables the KQV logic trace.
D enables the all-purpose data dump.
Note: Although you can specify a value for the new password, Sterling Connect:Direct for i5/OS
does not currently support this parameter.
Note: newpswd is not valid if the remote node is a Sterling Connect:Direct for i5/OS node.
Parameter values are case sensitive.