IBM TDS800 All in One Printer User Manual


 
180 Océ TDS800 User Manual
Set the folded package length)
1
Press the ‘Finishing’ card in the ‘Print’ section.
2 Press the function key ‘Folded package’.
3 Select ‘Length’.
4 Enter a range between 276 - 310 mm or 10.9 - 12.2 inch., in steps of 1 mm or
0.1 inch; default 297 mm or 12 inch
Set the binding strip
1
Press the ‘Finishing’ card in the ‘Print’ section.
2 Press the function key ‘Binding’.
3 Select binding enabled or disabled.
4 If you selected enabled enter a range between 15 - 30 mm or 0.6 - 1.2 inch, in
steps of 1 mm or 0.1 inch; default 20 mm or 0.8 inch.
Set the reinforcement
1
Press the ‘Finishing’ card in the ‘Print’ section.
2 Press the function key ‘Binding’.
3 Select ‘Reinforce’ enabled or disabled.
Note: Reinforcement is only possible with the Standard folding method
You can overrule the standard folding program with settings from the printer
driver or the scanner operator panel.
Find more information about Océ printer drivers in the on-line help. How to
make folding settings on the Océ TDS800 Scanner panel is described below.
See ‘Standard folding settings’ on page 179 for complete information about
defining default folding settings.
Fold settings from the Océ TDS800 scanner operator panel
1
Open the ‘Feeding’ card in the ‘Original’ section and press the ‘Legend
location’ function key to select the required legend location (‘Leading’ or
‘Trailing’).
Note: Make certain that your legend is always located on your left-hand
side to ensure correct positioning of the legend during folding.
2 Press the ‘Drawing method’ function key to select ‘Standard’, ‘Ericsson’ or
‘Afnor’ fold.