PRODUCT SAFETY DATA SHEET
Number
E-730-a-UK
Date
January 2001
Copyright © 2001 Océ-Technologies B.V., Venlo, NL
Model Océ TDS800 printer engine
Description
Electrophotographic printer, console model, plain paper, organic photoconductive drum,
powder toner .
Max. process speed
13 m/min
Dimensions Width
1720 mm
Depth
1146 mm
Height
1400 mm
Weight
939 kg
Vol ta ge
230 V 400 V 415 V
Frequency
50 Hz 50 Hz 50 Hz
Current-rated
16/12/11 A 11/6/7 A 11/6/6 A
Power consumption, low power
495 W
Power consumption, stand by
820 W
Power consumption, operation
4100 W
EPA
E
NERGY
S
TAR
®
* Power consumption
sleep mode
13 W (without controller)
Mains connection
Cables with plug
Safety class
I (IEC 536) Protective earth connection
Protection class
IP 20 (IEC 529)
Sound pressure level
(at bystander position)
Standby In operation
46 dB(A) main body 59 dB(A)
impulse L
i
= 1 dB(A)
Sound power level
59 dB(A) main body 70 dB(A)
Radio interference
Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A.
Radiation
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Heat emission
Standby 820 W; at continuous operation 4,1 kW
Ozone emission
0,02 mg/min at continuous operation
Room volume
Recommendation: min. 75 m
3
Room ventilation
Recommendation: min. 37,5 m
3
/h (natural ventilation)
For heat evacuation extra ventilation may be necessary
Use simulation at random
operation
Room volume and ventilation as recommended
Daily copy volume (much more than average) 1200 m
2
Total worktime 8 h
Ozone concentrations:
- Time weighted average < 0,001 mg/m
3
(<0,0005 ppm)
- Peak 0,0015 mg/m
3
( 0,0008 ppm)
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone 0,2 mg/m
3
(0,1 ppm)
Odour Perception Limit for ozone 0,04 mg/m
3
(0,02 ppm)
Consumables
Océ 9800 OPC (Océ Safety Data Sheet E-194)
Océ E1 Toner (Océ Safety Data Sheet E-198)
Océ Copying Materials
Additional safety information
The ozone filter does not have to be replaced to keep the ozone concentration in the
workplace below 0,04 mg/m
3
(i.e. the life of the filter equals that of the apparatus).
CE-Compliance Approved according to Approved according to EPA
E
NERGY
S
TA R
®
Low Voltage Directive EMC Directive
73/23/EEC 89/336/EEC