Intermec 700 Laptop User Manual


 
Configurable SettingsAppendix A
305700 Series Color Mobile Computer User’s Manual
Standard 2 of 5
Standard 2 of 5 is a discrete and self-checking symbology that uses the bars
to encode information and the spaces to separate the individual bars.
Action
Tap (+) to expand the Standard 2 of 5 parameter, select the setting to be
changed, then tap an option to change this setting or select an option from
the drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.4.1
Options
Decoding 0
1
Not active (default)
Active
Format 0
1
Identicon, 6 start/stop bars (default)
Computer Identics, 4 start/stop bars
Check digit 0
1
2
Not used (default)
Mod 10 transmitted
Mod 10 not transmitted
Bar code length 0
1
2
Any l ength
Minimum length (default)
Fixed lengths
Minimum length 001–254 Minimum length 1–254 (default is 6)
Fixed length 1 000–254 Fixed bar code length 0–254 (default is 0)
Fixed length 2 000–254 Fixed bar code length 0–254 (default is 0)
Fixed length 3 000–254 Fixed bar code length 0–254 (default is 0)
Note:IfBar code length =“1”thenMinimum length is entered. If Bar
code length =“2”thenFixed length 1, Fixed length 2,orFixed length 3
is entered.