Paradyne 3910 Network Card User Manual


 
DCP Operation
3-293910-A2-GN32-30 November 1996
F1
Poll List:Add
Command Complete
F2
F3
The
message
Command Complete appears on the LCD to indicate that the tributary modem will
be added to the control modem’
s poll list.
To exit this function and remain in the PList branch, press the
key
. To exit and return to the
Top-Level menu, press the
key
.
Acquire
The Acquir
e function does not appear in Remote mode.
Acquire allows you to acquire an active poll list consisting of all modems that are one tier
downstream. A modem will add to its poll list all downstream devices that respond to a poll.
To access Acquire from the Plist branch, make the following selections:
F1
Poll List: <
Add Acquire
F2
F3
Press the key until Acquire appears. Select Acquire.
NOTE
If an error message (OtherTestActive or Unable To Acquir)
appears on the second line of the LCD, move up one level in the
menu tree to clear the message and return to the PList Acquire
branch. The OtherTestActive message indicates that a test is
running which blocks the Acquire function. The Unable To Acquir
message indicates that the diagnostic network is in a busy state.
F1
Poll List:Acquir
Abort xxx yyy
F2
F3
The address field (xxx) increments sequentially from 001 to 256 as polls are transmitted from the
modem to the downstream modem(s). To be added to the modem’
s poll list, the device must
respond to a poll after receiving its address. The Acquire function can be canceled by selecting
Abort.