Table 3-8
Valid Ranges for VF Thresholds
VF Thresholds
Valid Ranges Default Values
Receive Signal Level High 0 dBm to –15 dBm Above –9 dBm
Receive Signal Level Low –16 dBm to –50 dBm Below –23 dBm
Signal to Noise Ratio 5 dB to 40 dB Below 23 dB
Non-Linear Distortion 15 dB to 50 dB Below 30 dB
Retrains 1 to 256 trains 15 trains per 15 minutes
Signal Quality Excellent (lowest)
Good
Fair
Poor
No Signal (highest)
Good
Near Echo
0ā—38 dBm
Above –20 dBm
Far Echo 0—38 dBm Above –20 dBm