Printronix P7000 Printer User Manual


 
Chapter 4 LinePrinter Plus Emulation (with PCL-II)
242
Auto LF
This option defines the printer actions when print data is received
past the forms width setting.
Enable (default). Performs an automatic carriage return and
line feed when data is received past the forms width.
Disable. Discards any data past the forms width.
Define LF Code
The Define LF Code option controls the action of the printer when it
receives a Line Feed code (hex 0A) from the host computer. If this
feature is enabled, each time the printer receives a Line Feed, it
inserts an additional Carriage Return code (hex 0D) into the data
stream. This feature is required if the host computer does not send
carriage returns to the printer.
LF = LF (default). Does not add a carriage return with a line
feed.
LF = CR + LF. Adds an extra carriage return with each line
feed.
Printer Select
Disable (default). Ignores the ASCII DC1 and DC3 control
codes.
Enable. Disables the printer when a DC1 control code is
received, and enables the printer when a DC3 control code is
received.