Fault Messages
323
B49 ERROR:
SDRAM # LOGICAL
BANKS*
No SDRAM DIMM is
not compatible with
the computer.
SDRAM DIMM
may not be
properly installed.
Cycle power to see if the
message clears, if not,
contact your authorized
service representative.
1
B50 ERROR:
SDRAM LOGIC
COMB BANKS*
No SDRAM DIMM is
not compatible with
the computer.
SDRAM DIMM
may not be
properly installed.
Cycle power to see if the
message clears, if not,
contact your authorized
service representative.
1
B50 STATUS: XX%
CLEAR FLASH
No Emulation software
sucessfully loaded
in RAM. Old
program being
deleted from flash
memory.
No action is required.
B51: ERROR SDA
LINE STUCK LOW
No Problem with I2C
bus. Either
SDRAM or PCI
card shorting out
the bus.
Contact your authorized
service representative.
1
B51 STATUS: XX%
PROGRAMMING...
No Status message
file sucessfully
loaded and is
being saved in
flash memory.
No action is required.
B55 STATUS: SEND
PROGRAM TO EC
No EC program
downloaded and
being programed
in EC.
No action is required.
Table 15. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation Solution