Printronix P7000 Printer User Manual


 
Chapter 7 Diagnosing Problems
332
HMR BANK FAN
FLT
Yes Sensors cannot
detect current in
fan circuit.
Check that fan cable is
connected. Check for
obstruction of vents and
fan airway; remove any
obstructions. Check for
items beneath the printer
blocking cabinet vents.
Power back on the
printer. If this message
recurs, contact your
authorized service
representative.
1
ILL EXT BUS ACC* No Fatal firmware
error on controller
board.
Contact your authorized
service representative.
1
ILLGL OPR ACCSS* No Fatal firmware
error on controller
board.
Contact your authorized
service representative.
1
INCOMPAT E-NET Yes Incompatible
network interface
card (NIC) is
installed.
Install a compatible NIC
to the printer then reboot.
If this message still
appears, contact your
authorized service
representative.
1
INTAKE FAN FAULT Yes Sensors cannot
detect current in
fan circuit.
See description for HMR
BANK FAN FLT.
Table 15. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation Solution