Q-Logic 8200 SERIES Computer Drive User Manual


 
B – Command Reference
Commands
B-26 SN0054628-00 A
Q
Show pss Command
Returns the status (Error or OK) and voltage information for each of the two power
supplies on the SANbox SSP.
Syntax show pss
Notes When looking at the fan side of the SANbox SSP, power supply 1 is on the right
side, and power supply 2 is on the left side.
See Also "Show ps Command" on page B-25
Show snmpv3 Command
Reports whether Simple Network Management Protocol is enabled or disabled.
Syntax show snmpv3
See Also "Disable snmpv3 Command" on page B-10
"Enable snmpv3 Command" on page B-11
Show Status Command
Returns the current status of all power supplies, fans, thermometers, and voltages
for SANbox SSP, and reports errors where detected.
Syntax show status
Show Therm Command
Returns the status, current temperature in Celsius and Fahrenheit, and the
minimum and maximum thresholds for the specified thermometer. SANbox SSP
has seven thermometers.
Syntax show therm
[therm number]
[*]
Keywords show therm [therm number]
An integer between 1 and 7, inclusive.
show therm [*]
* specifies all thermometers in SANbox SSP.
See Also "Show Therms Command" on page B-27