Q-Logic 8200 SERIES Computer Drive User Manual


 
5 – Maintaining the SANbox SSP
Replacing Hardware Components
SN0054628-00 A 5-7
Q
5.6.1
About the Transceivers
NOTE:
If the port is not being used, leave the rubber dust cover plugged into the
transceiver.
Always use the bail latch to remove and insert the transceiver; do not pull
on the transceiver body.
Always put the bail latch into the up position before inserting the Fibre
Channel cable.
SANbox SSP comes with a full set of transceivers already installed, one in each
port. QLogic’s transceivers include a bail latch that must be in the down position
before removing the transceiver and put in the up position before inserting the Fibre
Channel cable.
NOTE: QLogic highly recommends that you use only transceivers certified and
sold by QLogic. The transceivers that QLogic sells are Small Form-Factor
Pluggable industry standard transceivers. If another optical SFP
transceiver is used, other than one recommended and sold by QLogic
Corporation, the user must ensure compliance with UL recognized
standards and DHHS regulations.
To replace a transceiver:
1. Order replacement transceivers, part number 097-0007.
The kit includes four transceivers.
2. Pull down on the bail latch, and then pull the old transceiver out of the port.
3. Insert the new transceiver into the port.
4. Remove the rubber dust cover from the transceiver before inserting the Fibre
Channel cable.