7 Windows/Dialogs
7.7.11 Specify the Process ID
By specifying a task name (task number), it is possible to enable only the events that occurred in the
specified task.
7.7.11.1 Specify the Task
Only the events from a specified task can be detected. Events from other than a specified task can
also be detected.
Check the Enable check box included in the PID group of the event setting window. When this check
box is checked, the Detail... button to the right of it is enabled.
Click the Detail... button included in the PID group. This opens the Process ID Setting dialog box.
In the PID Setting area, specify the memory address in which to store the execution task, the data
size, and the task number (or task name). Mask can also be specified for the task number. In the
Condition group, click the radio button "==".
To enable events in other than a specified task, click the radio button "!=".
ATTENTION
In PID settings, always be sure to specify an even address for the Address area.
In the PID Event area, check the check box for the event you want to enable. Only the checked events
become the target to be debugged.