SMC Networks SMC8708L2 Switch User Manual


 
C
ONFIGURING
THE
S
WITCH
3-16
CLI – Specify the hostname, location and contact information.
Displaying Switch Hardware/Software Versions
Use the Switch Information page to display hardware/firmware version
numbers for the main board and management software, as well as the
power status of the system.
Field Attributes
Main Board
Serial Number – The serial number of the switch.
Number of Ports – Number of built-in ports.
Hardware Version – Hardware version of the main board.
Console(config)#hostname R&D 5 4-34
Console(config)#snmp-server location WC 9 4-154
Console(config)#snmp-server contact Ted 4-153
Console(config)#exit
Console#show system 4-83
System Description: 8*10GE L2 Switch
System OID String: 1.3.6.1.4.1.259.6.10.76
System Information
System Up Time: 0 days, 4 hours, 5 minutes, and 56.31 seconds
System Name: [NONE]
System Location: [NONE]
System Contact: [NONE]
MAC Address (Unit1): 00-0C-DB-21-11-33
Web Server: Enabled
Web Server Port: 80
Web Secure Server: Enabled
Web Secure Server Port: 443
Telnet Server: Enable
Telnet Server Port: 23
Authentication login: local RADIUS none
Jumbo Frame: Disabled
POST Result:
DUMMY Test 1 ................. PASS
UART Loopback Test ........... PASS
DRAM Test .................... PASS
Timer Test ................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Switch Int Loopback Test ..... PASS
Done All Pass.
Console#