477DME Wipe Settings for Independent Key Transitions
Chapter 6 DME Wipes
DME Wipe Settings for Independent Key
Transitions
You carry out independent key transition DME wipe setting operations using
the DME Wipe Adjust menu for each keyer.
For an overview of independent key transitions, see page 37.
This section describes the independent key transition DME wipe settings,
taking the M/E-1 >Key1 >Transition >DME Wipe Adjust menu as an example.
Basic Procedure for Independent Key Transition DME
Wipe Settings
Accessing the independent key transition DME wipe settings
menu
As an example, to access the M/E-1 >Key1 >Transition >DME Wipe Adjust
menu, carry out the following operation.
• In the menu control block, select the top menu selection button [M/E 1], and
select VF1 ‘Key1’ and HF6 ‘Transition’ to display the Transition menu for
key 1. Next, press [DME Wipe Adjust].
• Press the key delegation button [Key1] in the independent key transition
control block of the M/E-1 bank, then press the independent key transition
type [DME] twice in quick succession.
Carrying out the above operation displays the M/E-1 >Key1 >Transition
>DME Wipe Adjust menu (which will be referred to below as simply the Key1
DME Wipe Adjust menu).
Selecting the independent key transition DME wipe pattern
You select the independent key DME wipe pattern from the list of patterns
displayed in the menu.
To select a DME wipe pattern for independent key1 on the M/E-1 bank, use the
following procedure.
1
In the <Pattern Select> group of the Key1 DME Wipe Adjust menu, press
[1ch] for one-channel mode or [2ch] for two-channel mode.
The Pattern Select menu appears.