81DME Wipes
Chapter 1 MVS-8000 Functions
• 1381, 1391, 1393, 1394, 1396
When these pattern numbers are selected, you can set the center of the
transition effect.
• 2651, 2652
When these pattern numbers are selected, you can move the pattern for
each channel, or with values relative to the current position the two
channels simultaneously.
• 2801 to 2804, 2811 to 2814
When the these pattern numbers are selected, you can set the vertical
position as the brick slides in.
• 2851 to 2854, 2861 to 2864
When these pattern numbers are selected, you can set the pattern position
for each channel setting when the first transition completes.
Pattern limit: You can restrict the range of the transition as desired. However,
this is not available for a DME wipe in the independent key transition
control block.
For more details, see “Pattern Limit” (page 355).
Size: This can only be used when one of the following pattern numbers is
selected.
• 1201 to 1208, 1221 to 1224, 1251
• 2651, 2652, 2851 to 2854, 2861 to 2864
You can set the size of the image.
Crop: You can crop the image. It is also possible in 16:9 mode to crop both
sides, to convert the image to a 4:3 aspect ratio. For the execution of a
DME wipe crop transition, you can select from the following three
possibilities.
•Cut
•Last 5%
• Linear
When [Last 5%] is selected, you can set the [Release Transition] as
follows.
•Last 30%
•Last 5%
•Off
Notes
• When pattern numbers 1701 and 1702 are selected, crop cannot be used.
• The MVS-8000 does not support the [Last 5%] setting for [Release
Transition].
Relation Between DME Wipes and Other Effects
The relations between DME wipes and other effects are as follows.