Tektronix MTM400 Computer Monitor User Manual


 
Appendix A: Network Installation
A-8 MTM400 MPEG Transport Stream Monitor User Manual
The IP set-up is now complete. Close the MS-DOS window. With the IP Address
successfully set up, the network settings can be completed (refer to Resetting the
IP Address using the User Interface, page A-4).
The ARP command cannot be used if the unit already has an IP address - it will
only work if the IP is 0.0.0.0. (Refer to Resetting the IP Address to Factory
Default, page A-5 if the IP address is to be reset.)
Network Naming
If the MTM400 is to be accessible by network name rather than IP address, the
relationship between the IP address and the network name will need to be set up on
a DNS (domain name server) server on the network. This is not the name set up in
the Configuration screen. Contact your Network Administrator for help.
When the IP address has been set up, if the MTM400 is to be accessed from a
different net or subnet, the Gateway IP address and the Subnet Mask must be set
up. Contact your Network Administrator for help. The Gateway IP address and the
Subnet Mask values are set up in the Device Configuration Î Network
Settings… dialog. The MTM400 must be restarted in order for the settings to take
effect.
Network Latency
It has been noted that where access to a remote MTM400 uses a number of
internet/intranet links of varying speeds, the initial RUI download may be initiated
successfully, but the process then ceases. The network speed is outside of the
control of Tektronix, but it may be possible to alter some of the local network
settings to alleviate the problem.