Tektronix MTM400 Computer Monitor User Manual


 
Stream View
3-40 MTM400 MPEG Transport Stream Monitor User Manual
Test Selection
The Test: drop-down list allows the user to select and apply specific tests to the
PIDs in the stream. Tests on those PIDs to which the selected test is not applicable
are disabled.
The following PID tests can be selected from the Test: drop-down list:
Any PID Error
PID Bit Rate *
PCR Repetition
PCR Discontinuity
PCR Accuracy
PCR Overall Jitter **
PCR Frequency Offset**
PCR Drift Rate **
PTS Repetition
PID Variability *
Missing PID
Unreferenced PID
Continuity
Discontinuity
* Require Bit Rate Testing to be licensed (License Option 05, Table 1-2:
MTM400 options).
** Require PCR Testing to be licensed (see Table 1-2: MTM400 options).
The results of the tests are indicated by the Test icons. Where the test is
inapplicable, the icon will be white.
For most of the tests, the parameters applied to each PID can be varied by right-
clicking on the Test state button and selecting the Parameters… option.
Each of these tests and the associated parameters are described in the MTM400
MPEG Transport Stream Monitor Programmer Manual.
The results of tests applied here are not reflected in the PID Groups.