Tektronix MTM400 Computer Monitor User Manual


 
Stream View
MTM400 MPEG Transport Stream Monitor User Manual 3-35
Stream Bit Rate: The total bit rate of the stream.
Hex Display If enabled, the Transport Stream ID and the PID identities
are displayed in hex format. If disabled, they are displayed
in decimal format.
Test: Allows specific tests, selected from the drop-down list, to be
applied to all of the PIDs in the stream. The state of the test
is indicated for each PID by the Test icon. If a test is not
relevant to a PID, the test is disabled for that PID; the Test
icon indicates this.
The tests shown below are those that can be applied to each
PID where appropriate:
(See Test Selection, page 3-40)
Table
PID The PID number carrying the data.
Test Icon showing the state of the currently selected PID test:
Right-click this icon to open a popup menu that allows you
to reset the error, disable or enable monitoring of this event,
or adjust the parameters of the test.