Stream View
MTM400 MPEG Transport Stream Monitor User Manual 3-33
The maximum and minimum bit rate limits are set in the Limits dialog. Click on
the program bar to open the dialog box:
Only users logged on as Administrator can adjust bit rate limits. Users logged on
as User can only view the limits.
The maximum and minimum values can be set either by using the appropriate
slider bar or by entering a value in the numeric field. Values are expressed in
kilobytes per second. The Enabled checkbox must be selected before the limit will
be implemented. To confirm the settings select the OK button; to discard any
changes, select the Cancel button.
The Bit Rate Limits of all programs in a stream can be disabled and reset by
selecting the Clear Limits button at the top of the Programs screen.
PMT Test
The PMT column shows the results of the PMT test (MPEG Test 1.5) for specific
programs; green indicates a pass, red indicates a fail, and yellow indicates a
previous fail. Normally the test is enabled for all of the programs in a stream, but
programs with known problems can be excluded by right-clicking the test button
and selecting Disable; the button is colored gray.