Toshiba R100 Personal Computer User Manual


 
4 Replacement Procedures 4.19 Fluorescent Lamp
4.19 Fluorescent Lamp
This system uses LCD modules from the following supplier.
Type Part.No Supplier Section
12.1 inch G33C0000U110001 Toshiba Matsushita 4.19.1
Note: - When working with an LCD module, always use a flat, grounded table.
- Handle the backlight unit in the environment without dust, such as on the clean
bench. Keep the worktable free from any screws or other material that may
scratch the LCD surface.
- Use an anti-static or protective sheet.
- When replacing the FL unit, cover with a finger protector or similar to prevent
dirtying or scratching the LCD panel.
- Take care when handling the lamp. Excessive force may break the lamp.
- Take care not to deform the lamp reflector or allow it to get dirty.
- Ensure always that the power of the LCD module is turned off before
connecting or disconnecting cables and connectors.
4-50 PORTEGE R100 Maintenance Manual (960-440)