Xanté 3 Series Printer User Manual


 
4-40 PC Setupbb __________________________________________
Like any other precision instrument, the densitometer must be
calibrated before each use. Refer to its documentation for
instructions on calibrating and using the densitometer.
After calibrating the densitometer, use it to get density measurements
for the calibration page you printed.
Linearizing the Densitometer Data
Enter the densitometer measurements to calculate the adjustments
necessary to correct printer performance to a linear standard.
1. Click Enter Curve/Linearize (fig. 4.23). The Densitometer
Data Entry window appears (fig. 4.25).
Fig. 4.25 Densitometer Data Entry Window
2. Measure individual patches on the calibration page by placing
the page on a white background; then, center the
densitometer's lens over the patch and either click the black
button on top of the XD-1 or click the measure button on the
Densitometer Data Entry window (fig. 4.25). The
measurement appears in the box to the right of the Measure
button.