Zebra Technologies 1050020011570 Printer User Manual


 
Configuration
Control Panel Parameters
92
11342L-001 Rev. A 105SL User Guide 6/30/06
Set Delimiter Character
The delimiter character is a two-digit hex value used as a parameter place
marker in ZPL/ZPL II format instructions. See the ZPL II Programming
Guide Volume I for more information.
Note • Do not use the same hex value for the control, format, and
delimiter character. The printer must see different characters to
work properly.
Default: 2C (comma)
Range: 00 to FF
To change the value shown:
1. Press MINUS (-) to move to the next digit position.
2. Press
PLUS (+) to increase the value of the digit.
Select ZPL Mode
The printer remains in the selected mode until it is changed by this
parameter or by using a ZPL/ZPL II command. The printer accepts label
formats written in either ZPL or ZPL II, eliminating the need to rewrite any
ZPL formats that already exist. See the ZPL II Programming Guide for
more information on the differences between ZPL and ZPL II.
Default: ZPL II
Selections: ZPL II, ZPL
To change the value shown:
1. Press PLUS (+) or MINUS (-) to toggle between the options.
Select Media Power-Up Option
This parameter sets the action of the media when you turn on the printer.
Default: CALIBRATION
Selections: FEED, CALIBRATION, LENGTH, SHORT CAL, and NO
MOTION
Feed—feeds the labels to the first registration point.
Calibration—determines the length of the label and adjusts the
sensor settings.
Length—In continuous mode, feeds the last stored label length. In
noncontinuous mode, calibrates based on the maximum label length
setting (see Set Maximum Label Length on page 83).
Short Cal—calibrates label length using the current sensor settings.
No Motion—the media does not move. You must press
FEED to
cause the printer to resynch to the start of the next label.
To change the value shown:
1. Press PLUS (+) or MINUS (-) to scroll through the options.
Table 9 • Printer Parameters (Page 14 of 19)
Parameter
Action/Explanation
DELIMITER CHAR
- <,>2CH +
ZPL MODE
- ZPL II +
MEDIA POWER UP
- CALIBRATION +