93
Configuration
Control Panel Parameters
6/30/06 105SL User Guide 11342L-001 Rev. A
Select Head Close Option
This parameter sets the action of the media when you close the printhead.
Default: CALIBRATION
Selections: FEED, CALIBRATION, LENGTH, SHORT CAL, and NO
MOTION
• Feed—feeds the labels to the first registration point.
• Calibration—determines the length of the label and adjusts the
sensor settings.
• Length—In continuous mode, feeds the last stored label length. In
noncontinuous mode, calibrates based on the maximum label length
setting (see Set Maximum Label Length on page 83).
• Short Cal—calibrates label length using the current sensor settings.
• No Motion—the media does not move. You must press
FEED to
cause the printer to resynch to the start of the next label.
To change the value shown:
1. Press PLUS (+) or MINUS (-) to scroll through the options.
Select Backfeed Sequence
This parameter sets when label backfeed occurs after a label is removed in
some print modes. It has no effect in Rewind mode. This setting is
superseded by
~JS when received as part of a label format (see ZPL II
Programming Guide Volume I).
Default: DEFAULT (90%)
Selections: DEFAULT, AFTER, BEFORE, 10%, 20%, 30%, 40%, 50%,
60%, 70%, 80%, OFF
To change the value shown:
1. Press PLUS (+) or MINUS (-) to scroll through the options.
Adjust Label Top Position
This parameter adjusts the print position vertically on the label. Positive
numbers adjust the label top position farther down the label (away from the
printhead); negative numbers adjust the position up the label (toward the
printhead). The displayed value represents dots.
Default: +000
Range: –120 to +120 dots
To change the value shown:
1. Press PLUS (+) to increase the value.
2. Press
MINUS (-) to decrease the value.
Table 9 • Printer Parameters (Page 15 of 19)
Parameter
Action/Explanation
HEAD CLOSE
- CALIBRATION +
BACKFEED
- DEFAULT +
LABEL TOP +000
- +