Avaya X330W2-DS1 Network Router User Manual


 
WAN CLI Commands
Avaya X330W-2DS1 User’s Guide 141
The following are the show controllers command output fields:
Field Description
T1 1 is down Displays that the T1 controller 1 is not operating. The
controller’s state can be: up, down, or administratively down.
Loopback conditions are shown either as being locally looped
or remotely looped.
Cablelength Displays the current line buildout. Relevant for T1 lines only.
Remote alarm Any alarms detected by the controller are displayed. The
possible alarms are:
Transmitter is sending remote alarm.
Transmitter is sending alarm indication signal (AIS).
Receiver has loss of signal.
Receiver is getting AIS.
Receiver has loss of frame.
Receiver has remote alarm.
Receiver has no alarms.
Receiver has major alarm.
Framing Shows the current framing type. The default framing type for
E1 is CRC4. The default framing type for T1 is SF.
Line Code Displays the current line code. The default line code for E1 is
HDB3. The default line code for T1 is AMI.
Clock Source Displays the current clock source. The possible clock sources
are either Line or Internal.
Channel
Group
Displays the channel group number and timeslots.
Data in current
interval
(347 seconds
elapsed)
Displays the current accumulation period (from 1-900 seconds),
which rolls into a 24 hour accumulation every 15 minutes. The
oldest 15 minute period falls off the back of the 24 hour
accumulation buffer.
Line Code
Violations
Displays either no line code violations, the occurrence of a
Bipolar Violation, or the occurrence of an Excessive Zeros error
event.