Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
132 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
828.
User Code
Changed
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE
+++ ACC aaaa CODE ID=ccc ID=iii
h1rrlssssssaaaasNsD04t
<header>[#aaaa|NidiiiJVccc]
The passcode user ID
in the second line of
the report was
changed by the
operator with the
specified OPER ID.
829.
User Code
Changed
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE
+++ ACC aaaa AREA=a CODE ID=ccc ID=iii
h1rrlssssssaaaasNsD04t
<header>[#aaaa|Nria/idiiiJVccc]
The passcode user ID
in the second line of
the report was
changed by the
operator with the
specified OPER ID.
D7112
830.
User Code
Changed
(operator ID
not reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE
+++ ACC aaaa AREA=a CODE ID=ccc
h1rrlssssssaaaasNsD04t
<header>[#aaaa|NriaJVccc]
The passcode user ID
in the second line of
the report was
changed by the
operator with the
specified OPER ID.
D7112
831.
User Code
Changed
(users > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE
+++ACC aaaa CODE ID=cccc ID=iiii
h1rrlssssssaaaasNsD04t
<header>[#aaaa|NidiiiiJVcccc]
832.
User Code
Deleted
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE
+++ ACC aaaa CODE ID=ccc ID=iii
h1rrlssssssaaaasNsD05t
<header>[#aaaa|NidiiiJXccc]
The user ID specified
in the second line of
the report was deleted
by the operator with
the OPER ID shown.
D9112
833.
User Code
Deleted
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE
+++ ACC aaaa AREA= a CODE ID=ccc ID=iii
h1rrlssssssaaaasNsD05t
<header>[#aaaa|Nria/idiiiJXccc]
The user ID specified
in the second line of
the report was deleted
by the operator with
the OPER ID shown.
D7112
834.
User Code
Deleted
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE
+++ACC aaaa CODE ID=cccc
h1rrlssssssaaaasNsD05t
<header>[#aaaa|NJXcccc]
835.
User Code
Deleted
(operator ID
not reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE
+++ ACC aaaa AREA= a CODE ID=ccc
h1rrlssssssaaaasNsD05t
<header>[#aaaa|NriaJXccc]
The user ID specified
in the second line of
the report was deleted
by the operator with
the OPER ID shown.
D7112
836.
User Code
Deleted
(User ID# >
254 reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE
+++ACC aaaa CODE ID=cccc ID=iiii
h1rrlssssssaaaasNsD05t
<header>[#aaaa|NidiiiiJXcccc]
837.
User Code
Tamper
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPE
+++ ACC aaaa AREA=a ID=iii
h1rrlssssssaaaasNsD03t
<header>[#aaaa|Nria/idiiiJA]
Five attempts were
made in 5 min to
access the AREA in
the second line of the
report with the invalid
user ID shown.
1,
D9112
838.
User Code
Tamper
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPER
+++ ACC aaaa AREA=a
h1rrlssssssaaaasNsD03t
<header>[#aaaa|NriaJA]
Five attempts were
made in 5 min to
access the AREA in
the second line of the
report with the invalid
user ID shown.
1,
D7112