Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 43
3.2.21 Sescoa Super Speed (Message Type 7)
SIA Mode Description Sescoa Super
Speed Example
Table 72: Sescoa Super Speed (Message Type 7) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
7
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to
99. The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number has four digits.
I
Event code.
AA
Two- digit zone code or the first two digits user code.
C
Space if zone report, or the last digit user code.
Figure 21: Message sent to printer
mm/ddshh:mmsLxxSESsACCTsaaaa
+++sACCsaaaasEEEseeeeeeeeeeeeee
For lines that are grouped, Gxx appears
instead of Lxx.
Table 73: Sescoa Super Speed (Message Type
7) Printer Output
Characters Description
SES SESCOA Super Speed format.
Lxx Line number.
Gxx Grouped line numbers.
aaaa Account code.
EEE SESCOA Super Speed format event.
eeeeeeeeeeeeee Up to 14-characters of event
description.