Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
34 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.2.8 CFSK (Message Type I)
SIA Mode Description CFSK Example
<LF><CRC><I><sequence#><Receiver#><line#>[#aaaaaa|TTEE]<CR>
Table 49: CFSK (Message Type I) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
I (Capital I).
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account #
The communicator's account number, up to six digits.
TT
Event code.
EE
Zone/User ID.
3.2.9 Common Formats (Message Type <TAB>)
Defined Messages
SIA Mode Description SIA Example
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaaaaaaaaaaaaaa|data]<CR>
Table 50: Common Formats (Message Type <TAB>) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical Redundancy Check number.
Message Type
09 hex <TAB>
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number up to sixteen digits.
Data
This field contains message data codes such as event type, area number, point number,
identification number, and so on.
The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem
II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the program option selected. The
receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending
on the programmable option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C:
Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions.
Figure 12: Message sent to printer
MM/DDsHH:MMsLxxSIA ACCT aaaa
+++ TEXT 1
+++ TEXT 2