Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 93
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
372.
Force Close
Late
(7112 Only)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE
h1rrlssssssaaaasCsssst
<header>[#aaaa|NCF]
373.
Forced Close
Late by Area
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE
+++ ACC aaaa AREA=a ID=iii
h1rrlssssssaaaasCsiiit
<header>[#aaaa|Nria/idiiiCF]
A user with the ID in
the second line of the
report armed the
AREA in the second
line of the report after
the programmed
closing time while
points in the AREA
were faulted. Faulted
points were not armed.
374.
Forced Close
Late by Area
(users > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE
+++ACC aaaa AREA=aa ID=iiii
h1rrlssssssaaaasCiiiit
<header>[#aaaa|Nriaa/idiiiiCF]
375.
Forced Close
Perimeter
Delay by Area
(ID not
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY
+++ ACC aaaa AREA=a
h1rrlssssssaaaasCsssst
<header>[#aaaa|NriaNF]
A user with the ID in
the second line of the
report has delay armed
the perimeter of the
AREA while points in
the AREA were
faulted. Faulted points
were not armed.
1,
D7112
376.
Forced Close
Perimeter
Delay by Area
(ID not
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY
+++ ACC aaaa AREA=a
h1rrlssssssaaaasCsssst
<header>[#aaaa|NriaNF]
A user with the ID in
the second line of the
report armed the
perimeter of the AREA
while points in the
AREA were faulted.
Faulted points were
not armed.
377.
Forced Close
Perimeter
Delay by Area
(User ID# >
254 reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY
+++ACC aaaa AREA=aa ID=iiii
h1rrlssssssaaaasCiiiit
<header>[#aaaa|Nriaa/idiiiiNF]
378.
Forced Close
Perimeter
instant by
Area
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST
h1rrlssssssaaaasCsiiit
<header>[#aaaa|Nria/idiiiNF]
A user with the ID in
the second line of the
report armed the
perimeter of the AREA
while points in the
AREA were faulted.
Faulted points were
not armed.
1,
D7112
379.
Forced Close
Perimeter
instant by
Area(ID not
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST
h1rrlssssssaaaasCsssst
<header>[#aaaa|NriaNF]
A user with the ID in
the second line of the
report armed the
perimeter of the AREA
while points in the
AREA were faulted.
Faulted points were
not armed.
1.
380.
Forced Close
Perimeter
Instant by
Area (User
ID# > 254
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST
+++ACC aaaa AREA=aa ID=iiii
h1rrlssssssaaaasCiiiit
<header>[#aaaa|Nriaa/idiiiiNF]