Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
62 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
12.
AC Fail Since
Last Call
Printer:
D6500 Mode:
SIA Mode:
+++ ACC aaaa AC FAILURE
h1rrlssssssaaaaSPsssst
<header>[#aaaa|OAT]
No AC power. Control
panel is running on
battery power only.
You can program the
control panel to defer
this report.
5.
13.
AC Restoral
(Area
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa AC RESTORAL
+++ACC aaaa AREA=aa
h1rrlssssssaaaasRsss0t
<header>[#aaaa|NriaaAR]
14.
AC Restoral
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa AC RESTORAL
h1rrlssssssaaaasRsss0t
<header>[#aaaa|NAR]
AC power restored. D7112
15.
AC Restoral
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaa RESTORAL ZN z
h1rrlssssssaaaasRssszt
<header>[#aaaa|NURO]
2,
z = 0
16.
AC Restored
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt AC RESTORED RCVR rr
h1rrssssssssssssXss14t
<header>[NAR]
17.
AC Troubled
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt AC TROUBLED RCVR rr
h1rrssssssssssssXss13t
<header>[NAT]
18.
Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
h1rrlssssssaaaasAsssst
<header>[#aaaa|NBA]
Unexpanded alarm
report. Alarm report
from the POINT in the
AREA specified in the
second line of the report.
1,10
19.
Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM ZN z
h1rrlssssssaaaasAssszzt
<header>[#aaaa|NBAz]
2,9
20.
Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM ZN zyy
h1rrlssssssaaaasAszyyt
<header>[#aaaa|NBAzyy]
21.
Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM ZN zxx
h1rrlssssssaaaasAssxxt
<header>[#aaaa|NBAxx]
22.
Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM ZN 16
h1rrlssssssaaaasAss16t
<header>[#aaaa|NBA16]
Alarm condition on
the zone number
shown.
23.
Alarm
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|NriaaBApppp]
24.
Alarm
(with Ground
Fault)
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa GROUND FAULT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|NriaaBApppp]
25.
Alarm
(Area Not
Reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ ACC aaaa POINT=ppp
+++ ACC aaaa ID=iii POINT=ppp
h1rrlssssssaaaasAspppt
<header>[#aaaa|NBAppp]
Unexpanded alarm
report. Alarm report
from the POINT in the
AREA specified in the
second line of the
report.