Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 31
3.2.4 Ademco 4-2 Express (Message Type c)
SIA Mode Description 4-2 Express
Example
<LF><CRC><c><sequence#><receiver#><line#>[#aaaa|XY]<CR>
Table 43: Ademco 4-2 Express (Message Type c) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
c
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the
D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number has four digits.
XY
Event code and Zone number.
Figure 10: Message sent to printer
mm/ddshh:mmsLxxsE42sACCTsaaaasEVENT=XY
For lines that are grouped, Gxx appears
instead of Lxx.
Table 44: Ademco 4-2 Express (Message
Type c) Printer Output
Characters Description
E42 Ademco 4-2 Express format.
Lxx: Line number.