Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 135
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
865.
Walk Test
Start
(Invisible
Points)
(users > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WALK TEST START
+++ACC aaaa INVISIBLE POINTS
+++ACC aaaa AREA=aa ID=iiii
h1rrlssssssaaaasTsssFt
<header>[#aaaa|Nriaa/idiiiiTS]
866.
Walk Test
Start
(no user)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WALK TEST START
+++ACC aaaa AREA=a
h1rrlssssssaaaasTsssFt
<header>[#aaaa|NriaTS]
867.
Walk Test
Start
(users > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WALK TEST START
+++ACC aaaa AREA=a ID=iiii
h1rrlssssssaaaasTsssFt
<header>[#aaaa|Nria/idiiiiTS]
868.
Was Force
Armed
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WAS FORCE ARMED
h1rrlssssssaaaasWsssst
<header>[#aaaa|NCW]
Account armed with
zones or points faulted.
The faulted zones or
POPITs were not
armed. Zones, areas,
or points that were not
armed are indicated
by a TROUBLE or
SHUNTED report.
869.
Watchdog
Reset
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaa RESTORAL ZN 9
h1rrlssssssaaaasRsss9t
<header>[#aaaa|NUR9]
Battery restoral report,
control panel reboot,
watchdog reset, power
reset, or ResetBye with
RAM.
Control panel reboot,
watchdog reset, power
reset, or ResetBye with
RAM (can also be
battery restoral report
for D7112).
870.
Watchdog
Reset
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET
h1rrlssssssaaaasNsD09t
<header>[#aaaa|NYW]
The control panel’s
watchdog reset. This is
a non-emergency
troubleshooting
message. If it is
followed by SDI ##,
call Bosch Security
Systems Technical
Support during normal
business hours for help
in interpreting the
message.
871.
Watchdog
Reset
(SDI Device
and Point
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET
+++ ACC aaaa POINT=ppp SDI=ddd
h1rrlssssssaaaasNspppt
<header>[#aaaa|NpidddYWppp]
The control panel's
watchdog reset. This is
a non-emergency
troubleshooting
message. If it is
followed by SDI ##,
call Bosch Security
Systems Technical
Support during normal
business hours for help
in interpreting the
message.
872.
+5V Restored
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt +5 RESTORED RCVR rr
h1rrssssssssssssXsss4t
<header>[NYQ]