3.1.22 Silent Knight FSK0 (Message Type 1)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Silent Knight
FSK0 Example
h 1 r r l s s s s s s a a a a s E s s s Z t
Table 25: Silent Knight FSK1 (Message Type m) Byte Description
# Title Description
1 Header Character
(h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
1
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6-11 Spaces
Six spaces.
12-15 Account Number
Four digit account number.
16 Spaces
One space.
17 E
Event code.
18-20 Space
Three spaces.
21 Zone number
Zone number.
22 Trailer Character
Typically, HEX 14.
Optional Silent Knight SK1 (Message Type m):
If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to 1, the following output is used.
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Silent Knight
FSK1 Example
h m r r l s a a a a a a a a “ Z Z “
. . . t
Table 26: Optional Silent Knight SK1 (Message Type m) Byte Description
# Title Description
1 Header Character
(h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
m
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6 Spaces
One space.
7-14 Account Number
Maximum eight-digit account code. If the account code is less than eight digits, enter the
actual number of digits without a leading space.
15
Separator.
16-17 ZZ
First zone number, up to eight reports, one report has two digits.
18
Separator.
19 ***
More data.
21 Trailer Character