3.2.16 Robofon (Message Type j)
SIA Mode Description Robofon
Example
<LF><CRC><j><sequence#><receiver#><line#>[#aaaaaa|EE]<CR>
Table 65: Robofon (Message Type j) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
j
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account #
The communicator's account number has up to six digits.
EE
Event code.
3.2.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g)
SIA Mode Description 4-16-1 Example
<LF><CRC><g><sequence#><receiver#><line#>
[#aaaaaa|CCCCsCCCCsCCCCsCCCCsC]<CR>
Table 66: Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
g
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
Account#
The communicator's account number has up to six digits.
CCCC
Channels 1 to 4.
s
One space.
CCCC
Channels 5 to 8.
s
One space.
CCCC
Channels 9 to 12.
s
One space.
CCCC
Channels 13 to 16.
s
One space.
C
Supervisory channel.