Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
38 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.2.13 ITI (Message Type I)
SIA Mode Description ITI Example
<LF><CRC><I><sequence#><receiver#><line#>[#aaaaa|GIZZEWN]<CR>
Table 61: ITI (Message Type I) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
I (Captial I).
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number has up to six digits.
G
Group number.
I
O/C User ID.
ZZ
Zone number.
E
Condition code.
W
Protection level was.
N
Protection level now.
3.2.14 Link Test (Message Type <TAB>)
SIA Mode Description Link Test
Example
<LF><CRC><TAB><sequence#><receiver#> []<CR>
The D6600/D6100 can automatically generate this message at the preprogrammed intervals.
Table 62: Link Test (Message Type <TAB>) Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
<TAB>
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.