Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
32 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.2.5 Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f)
SCANCOM 5-8-1, 6-8-1 - available upon request
SIA Mode Description High Speed
Example
<LF><CRC><f><sequence#><receiver#><line#>[#aaaaaa|CC CCsCCCCsC]<CR>
Table 45: Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
f
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the
D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number has up to six digits.
CCCC
Channels 1 to 4.
s
One space.
CCCC
Channels 5 to 8.
s
One space.
C
Supervisory channel.
Figure 11: Message sent to printer
mm/ddshh:mmsLxxsHGHsACCTsaaaaaa+++sACC
saaaaaasCCCCsCCCCsC
For lines that are grouped, Gxx appears
instead of Lxx.
Table 46: Ademco High Speed, 4-8-1 (Message
Type f) Printer Output
Characters Description
HGH Ademco High Speed format.
Lxx: Line number.
Gxx Grouped line numbers.