Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
64 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
36.
Alarm Door
Forced
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa DOOR FORCED
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|NriaaDFpppp]
37.
Alarm Exit
Error
(Area Not
Reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ ACC aaaa EXIT ERROR
h1rrlssssssaaaasAspppt
<header>[#aaaa|NidiiiEAppp]
Unexpanded alarm
report. Alarm report
from the POINT in the
AREA specified in the
second line of the
report.
38.
Alarm Exit
Error
(points < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa EXIT ERROR
+++ACC aaaa AREA=a ID=iii POINT=ppp
h1rrlssssssaaaasAspppt
<header>[#aaaa|Nria/idiiiEAppp]
39.
Alarm Exit
Error
(points > 254,
user < 255))
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa EXIT ERROR
+++ACC aaaa AREA=aa ID=iii POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|Nriaa/idiiiEApppp]
40.
Alarm Exit
Error
(points > 254,
user > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa EXIT ERROR
+++ACC aaaa AREA=aa ID=iiii POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|Nriaa/idiiiiEApppp]
41.
Alarm Exit
Error
(with Ground
Fault)
(points > 254,
user < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa EXIT ERROR, GROUND FAULT
+++ACC aaaa AREA=aa ID=iii POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|Nriaa/idiiiEApppp]
42.
Alarm Exit
Error
(with Ground
Fault)
(points > 254,
user > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM REPORT
+++ACC aaaa EXIT ERROR, GROUND FAULT
+++ACC aaaa AREA=aa ID=iiii POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|Nriaa/idiiiiEApppp]
43.
Alarm Fire
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FIRE FR z
h1rrlssssssaaaasFssszt
<header>[#aaaa|NFAz]
44.
Alarm
Silenced
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALARM SILENCED
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaFSppppt
<header>[#aaaa|NriaaFLpppp]
45.
All Points
Tested
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ALL PTS TESTED
h1rrlssssssaaaasRsssFt
<header>[#aaaa|NTC]
46.
Analog
Restoral
(points < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasRspppt
<header>[#aaaa|NriaANppp]
47.
Analog
Restoral
(points < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE
+++ACC aaaa SENSOR DIRTY
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasRspppt
<header>[#aaaa|NriaANppp]