Optional Silent Knight FSK1 (Message Type m)
If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to1, the following output is used.
SIA Mode Description Silent Knight
FSK1 Example
<LF><CRC><m><sequence#><receiver#><line#>[#aaaa|ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ]<
CR>
Table 76: Optional Silent Knight FSK1 (Message Type m) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
m
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to
99. The receiver uses Line 0 (zero) for internal messages.
account #
The communicator's account number has four digits.
ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”Z
Z
Up to eight reports. One report has two digits. The quote (“) is the separate character.
Table 77: Silent Knight FSK1 Optional Outputs
To Automation Report Code Description
2 5 16 = 0(EEZZ) 2 5 16 = 1(ZZ)
Note
00 Alarm Panic PAss 00
01 to 08 Alarm 01 to 08 sA0x 01 to 08 x = 1 to 8
09 Holdup Hass 09
10 to 19 Alarm 10 to 19 sA1x 10 to 19 x = 0 to 9
20 to 29 Alarm Restore 10 to 19 sH1x 20 to 29 x = 0 to 9
30 Test Code sXss 30
31 Trouble Line 1 LT01 31
32 Trouble Line 2 LT02 32
33 Expand Trouble ETss 33
34 Forced Access DFss 34
35 Restore Line 1 LR01 35
36 Restore Line 2 LR02 36
37 Expand Restore ERss 37
38 Cancel Code OCss 38
39 Data Lost RTss 39
40 Closing CL00 40
41 to 49 Closing 01 to 09 CL0x 41 to 49 x = 1 to 9
50 to 59 Bypass 10 to 19 sB1x 50 to 59 x = 0 to 9
60 Trouble AC ATss 60
61 to 68 Trouble 01 to 08 sT0x 61 to 68 x = 1 to 8
69 Trouble BAT YTss 69
70 Restore AC ARss 70
71 to 78 Restore 01 to 08 sRss 71 to 78
79 Restore BAT YRss 79
80 Access DS00 80