Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 33
3.2.6 ADT SIA (Message Type <TAB>)
SIA Mode Description ADT SIA
Example
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|<E><damm-dd-
yytihh:mm:ss>data]<CR>
Table 47: ADT SIA (Message Type <TAB>) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
09 hex <TAB>.
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number up to sixteen digits.
E
Event Code (refer to Appendix G ADT SIA Report Codes on page 149).
damm-dd-yytihh:mm:ss
Date and time.
Data
This field contains message data codes such as event type, area number, point number,
identification number.
3.2.7 Caller ID (Message Type <TAB>)
SIA Mode Description SIA Example
<LF><CRC><TAB><sequence#><receiver#><line#>[&TTTTTTTTTTTTTTTT]<CR>
Table 48: Caller ID (Message Type <TAB>) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical Redundancy Check number.
Message Type
<TAB>
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
&
Origin ID Block.
T
Up to 16-digit Caller ID.