Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
68 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
88.
Bypass, Sked
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SKED BYPASS
+++ ACC aaaa AREA=a POINT=ppp SKED=kk
h1rrlssssssaaaasNspppt
<header>[#aaaa|Nria/aikkUBppp]
The POINT in the
AREA in the second
line of the report is
faulted, and was
bypassed when the
system was armed by
the specified Sked.
89.
Bypass,
Swinger
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasNspppt
<header>[#aaaa|NriaUBppp]
The POINT in the
AREA in the second
line of the report (that
was programmed for
swinger bypass) is
faulted, and was
bypassed while the
system was armed. If
the point restores while
the system is armed, it
returns to the system,
and is ready to detect
faults.
90.
Cancel
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL REPORT
h1rrlssssssaaaas\sssst
<header>[#aaaa|NOC]
A system in alarm was
disarmed before the
bell time expired. The
specified point sends a
Cancel Report for the
alarmed area.
91.
Cancel
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ID i
h1rrlssssssaaaas\sssit
<header>[#aaaa|NOCi]
92.
Cancel
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ID iyy
h1rrlssssssaaaas\siyyt
<header>[#aaaa|NOCiyy]
93.
Cancel Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM
+++ ACC aaaa AREA=a ID=iii
h1rrlssssssaaaas\sssst
<header>[#aaaa|Nria/idiiiBC]
The system armed or
disarmed with a
passcode or
COMMAND 1
reporting no User ID.
1.
94.
Cancel Alarm
(Area Not
Reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM
+++ ACC aaaa ID=iii
h1rrlssssssaaaas\sssst
<header>[#aaaa|NidiiiBC]
The system armed or
disarmed with a
passcode or
COMMAND 1
reporting no User ID.
95.
Cancel Alarm
(Non-Fire)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM
+++ ACC aaaa AREA=a ID=iii
h1rrlssssssaaaas\siiit
<header>[#aaaa|Nria/idiiiBC]
The system armed or
disarmed with a
passcode or
COMMAND 1
reporting no User ID.
96.
Cancel Alarm
(Non-Fire)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM
+++ACC aaaa AREA=a
h1rrlssssssaaaas\sssst
<header>[#aaaa|NriaBC]
97.
Cancel Alarm
(Non-Fire)
(users > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM
+++ACC aaaa AREA=aa ID=iiii
h1rrlssssssaaaas\iiiit
<header>[#aaaa|Nriaa/idiiiiBC]