Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix I: D6600 SafeCom Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 165
Table 115: Explanation of Printer Output Items
Character Meaning
dd/dd
Month and day (MM/DD).
tt:tt
Time of message receipt (HH:MM).
S
SafeCom
xx
Line card number, range: 01 to 08.
n
Radio channel number, range: 1 to 8.
aaa
Radio account number (in hex), range: 001 to 9C4.
>
If exists, the signal is in high priority.
e
Error code (for dialer error signals only), range: 0 to 6.
i
Input number, range: 1 to 8.
z
Zone number, range: 1 to 8.
u
User number, range: 1 to 8.
(aaaa)
Control panel account number.
e
ee
eee
Event code.
eeee eeee
Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only).
t
Type code.
z
zz
zzz
Zone (or contact) code.
gg
Group number.
f
Function code.
aa
Area code.
XXXXXXXX
Translation text embedded (only when valid digital XLAT is selected for the radio account).
TTTTTTTT
Event type can be NEW, RESTORE, or PRIOR (Ademco Contact ID only).
q
Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message) (Ademco Contact ID
only).