Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 15
3.1.12 FBI Super Fast (Message Type F)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
FBI Super Fast
Example
h F r r l s s s s s s a a a a T Z Z E s s t
Table 14: FBI Super Fast (Message Type F) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
F (Capital f).
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group Number
Line number in the receiver gateway that sent the message.
6-11 Spaces
Six spaces.
12-15 Account Number
Account number, four digits.
16 T
Zone type.
17-18 ZZ
Zone number.
19 E
Event type.
20-21 Spaces
Two spaces.
22 Trailer Character
Typically, this is HEX 14.
3.1.13 ITI (Message Type I)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
ITI Example
h I r r l s s s a T a a a a G I Z Z E W N t
Table 15: ITI (Message Type I) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
I (Capital i).
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group Number
Line number in the receiver gateway that sent the message.
6-8 Spaces
Three spaces.
9 Account Number
First digit account number.
10 Panel Type
Control panel Type.
11-14 Account Number
Next four digit account number.
15 G
Group number.
16 I
Open/close (O/C) User ID.
17-18 ZZ
Zone number.
19 E
Condition code.
20 W
Protection level was.
21 N
Protection level is.
22 Trailer Character
Typically, this is HEX 14.
3.1.14 Link Test (Message Type 1)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Link Test
Example
h 1 r r 0 s s s s s s s s s s s
@
s s s s t