Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix E: Pulse Output
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 141
Appendix E: Pulse Output
Table 97 to Table 105 (on page 145) vary
depending on the account number
specified and the digit parameter
programmed using the drop-down menus
in Menu Item 3.1.7 Event 3/1 or 4/1
(Figure 25).
The output of the receiver depends on the reporting
digit. Use the settings in Figure 25 that can be changed
by the user:
Reporting digits 0 to 9 and A are alarms
Reporting digit B is an opening
Reporting digit C is a closing
Reporting digit D is a cancel
Reporting digit E is a restore
Figure 25: D6200 Receiver Software Line Card
Configuration
Table 97: Pulse 3/1 Format
# Event Account
Number
Reporting
Digit
Device/Mode Displays
1.
ALARM 123 4
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 ALARM_ZN 4
[10]1011sssssss123sAsss4[13]
[10]602415[9]00030101[#s123|NBA4][13]
2.
OPENING 123 B
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 OPENING
[10]1011sssssss123sOssss[13]
[10]AA4214[9]00040101[#s123|NOP][13]
3.
CLOSING 123 C
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 CLOSING
[10]1011sssssss123sCssss[13]
[10]F94B14[9]00050101[#s123|NCL][13]
4.
CANCEL 123 D
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 CANCEL
[10]1011sssssss123s\ssss[13]
[10]FBCE14[9]00060101[#s123|NOC][13]
5.
RESTORE 123 E
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 RESTORE
[10]1011sssssss123sRssss[13]
[10]FC2214[9]00070101[#s123|NUR][13]
6.
TROUBLE 123 F
Printer:
D6500 Mode:
SIA Mode:
DD/DD TT:TT L01 ACCT 123 TROUBLE
[10]1011sssssss123sTssss[13]
[10]ACD414[9]00080101[#s123|NBT][13]