Bosch Appliances D6100 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 67
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
77.
Bypass,
Remote
(Call back)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS
+++ ACC aaaa AREA=a POINT=ppp PH#=h
h1rrlssssssaaaasNspppt
<header>[#aaaa|Nria/phhUBppp]
The POINT in the
AREA specified in the
second line of the
report is faulted, and
was bypassed by a
RAM through the
specified phone line.
78.
Bypass,
Remote
(No Call back)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasNspppt
<header>[#aaaa|NriaUBppp]
The POINT in the
AREA specified in the
second line of the
report is faulted, and
was bypassed by a
RAM through the
specified phone line.
79.
Bypass Restore
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa POINT=ppp
h1rrlssssssaaaaRBspppt
<header>[#aaaa|NUUppp]
80.
Bypass Restore
(points < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaRBspppt
<header>[#aaaa|NriaUUppp]
81.
Bypass Restore
(point < 255)
(Fire point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa FIRE POINT
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaRBspppt
<header>[#aaaa|NriaFUppp]
82.
Bypass Restore
(points < 255)
(Supervisory
point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa SUPERVISORY POINT
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaRBspppt
<header>[#aaaa|NriaSUppp]
83.
Bypass Restore
(points < 255)
(Waterflow
point))
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa WATERFLOW POINT
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaRBspppt
<header>[#aaaa|NriaWUppp]
84.
Bypass Restore
(point > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaRBppppt
<header>[#aaaa|NriaaUUpppp]
85.
Bypass Restore
(point > 254)
(Fire point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa FIRE POINT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaRBppppt
<header>[#aaaa|NriaaFUpppp]
86.
Bypass Restore
(point > 254)
(Supervisory
point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa SUPERVISORY POINT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaRBppppt
<header>[#aaaa|NriaaSUpppp]
87.
Bypass Restore
(point > 254)
(Waterflow
point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE
+++ACC aaaa WATERFLOW POINT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaRBppppt
<header>[#aaaa|NriaaWUpppp]